Auto-Zero Debug Logging Guide

This document explains the debug logging added to track auto-zero behavior in real-time.

Enable Debug Logging

Add this to your configuration.yaml:

logger:
  default: info
  logs:
    custom_components.autopi: debug

Log Tags and What They Mean

Initialization Phase

  • [AUTO-ZERO INIT] - Auto-zero manager initialization
  • Shows when the manager starts and whether auto-zero is enabled
  • Shows how many metrics are being restored from storage

  • [SENSOR INIT] - Individual sensor creation

  • Shows each sensor being created and whether it supports auto-zero

Startup/Restoration Phase

  • RESTORED - A previously zeroed metric was restored from storage
  • Shows the metric name, vehicle, and how long ago it was zeroed

  • SKIPPED - A stored zero state was too old (>24 hours) and not restored

  • Prevents ancient zero states from persisting forever

Runtime Evaluation Phase

  • [SENSOR AUTO-ZERO] - Sensor-level auto-zero checks
  • Shows when a sensor checks if it should be zeroed
  • Special note: "STARTUP PROTECTION" means preventing stale data on HA restart

  • [SENSOR DATA] - Raw sensor data

  • Shows the actual value and age of data from the API

  • [AUTO-ZERO EVAL] - Auto-zero manager evaluation

  • Shows the age of data vs. the 15-minute threshold
  • Shows whether the metric is currently zeroed

  • is_metric_zeroed check - Quick check if a metric is already zeroed

  • Used during startup to prevent showing stale data

Action Phase

  • [AUTO-ZERO ACTION] ZEROING - Metric is being zeroed
  • Shows when data crosses the 15-minute threshold

  • [AUTO-ZERO ACTION] UN-ZEROING - Metric is being restored

  • Shows when fresh data arrives (≤15 minutes old)

  • [AUTO-ZERO UPDATE] - Updates to already-zeroed metrics

  • Shows when a zeroed metric gets new (but still stale) data

Storage Phase

  • [AUTO-ZERO SAVE] - Persistence operations
  • Shows when state is saved to disk
  • Lists all metrics being saved

Example Log Flow

Scenario 1: Home Assistant Startup with Stale Data

[AUTO-ZERO INIT] Initializing auto-zero manager
[AUTO-ZERO INIT] Auto-zero manager initialized, auto_zero_enabled=True
Processing 3 zeroed metrics from storage
RESTORED zeroed state for Engine RPM (OBD) on vehicle 123 (zeroed 0.5 hours ago)
[SENSOR INIT] Created sensor Engine RPM for vehicle 123 (field_id: obd.rpm.value, auto-zero capable: True)
[SENSOR AUTO-ZERO] Checking Engine RPM on vehicle 123: auto_zero_enabled=True
is_metric_zeroed check: Engine RPM (OBD) on vehicle 123 IS ZEROED (zeroed 30.0 minutes ago)
[SENSOR AUTO-ZERO] Engine RPM for vehicle 123 is marked as zeroed and no data available, returning 0 (STARTUP PROTECTION)

Scenario 2: Data Becoming Stale

[SENSOR DATA] Engine RPM for vehicle 123 has value 0 (last_seen: 2025-01-15T10:00:00, age: 16.5 min)
[AUTO-ZERO EVAL] Engine RPM (OBD) on vehicle 123: last_seen 16.5 min ago (threshold 15 min), currently zeroed: False
[AUTO-ZERO ACTION] ZEROING Engine RPM (OBD) for vehicle 123 - data is 16.5 minutes old (threshold: 15 min)
[AUTO-ZERO SAVE] Scheduling save operation with 1 zeroed metrics
[SENSOR AUTO-ZERO] RETURNING 0 for Engine RPM on vehicle 123 (auto-zero applied)

Scenario 3: Fresh Data Arriving

[SENSOR DATA] Engine RPM for vehicle 123 has value 850 (last_seen: 2025-01-15T10:20:00, age: 2.1 min)
[AUTO-ZERO EVAL] Engine RPM (OBD) on vehicle 123: last_seen 2.1 min ago (threshold 15 min), currently zeroed: True
[AUTO-ZERO ACTION] UN-ZEROING Engine RPM (OBD) for vehicle 123 - fresh data received (2.1 minutes old)
[SENSOR AUTO-ZERO] Engine RPM on vehicle 123 NOT zeroed, returning actual value 850

Troubleshooting with Logs

Issue: Sensor shows stale value on startup

Look for: - Missing [SENSOR AUTO-ZERO] ... STARTUP PROTECTION log - Check if is_metric_zeroed check shows the metric as zeroed - Verify RESTORED log shows the metric was loaded from storage

Issue: Sensor not zeroing when expected

Look for: - [AUTO-ZERO EVAL] to see the actual age vs. threshold - Check if auto_zero_enabled=True in the logs - Verify the field_id is in the auto-zero capable list

Issue: Sensor zeroing too quickly

Look for: - [SENSOR DATA] to see the actual last_seen timestamp - The age calculation might show the data is older than expected - Check your AutoPi device's reporting frequency

Performance Note

These debug logs are verbose and should only be enabled when troubleshooting. Disable debug logging for normal operation to reduce log size.